DOLLINGER Hydrogen Purification System  

HPS - Hydrogen Purification System

The Dollinger Hydrogen Purification System (HPS) is a self-contained, automatic purification system for generator coolant gas incorporating an automatic dual-chamber desiccant dryer, particulate after-filter, positive displacement blower, and optional coalescing pre-filter and carbon bed adsorber.

THE DOLLINGER HPS PROVIDES CLEAN, DRY HYDROGEN:

• During highest contamination loading.
• During idle time with less natural circulation boost.
• While automatically eliminating operator attention.
• By positively purging contaminants from the hydrogen system.

Applications:

The Dollinger HPS is used in electrical power generating plants to dry and purify the hydrogen used as a coolant for generators. Water, oil, and other contaminants cause corrosion in retaining and zone rings, lead carbonate formation, increased windage and other potentially serious consequences. Single tower dryers require constant attention because of their manual operation. Upgraded models include automatic operation but neglect improvements in reliability and the critical purification needs during "turning gear" when the generator is exposed to increased contamination loads and reduced hydrogen circulation. The Dollinger HPS was specifically designed to remove each contaminant and provide a continuous flow of clean, dry hydrogen throughout all phases of generator operation.

Superior Performance:

Maximum contaminant removal is provided by a completely packaged system incorporating a desiccant dryer to remove water vapor, an after-filter to remove particulates, an optional coalescing pre-filter to remove liquids and an optional carbon adsorber to remove hydrocarbons.

The positive displacement, gas-tight blower ensures maximum circulation of hydrogen through the generator and purifier during peak load, as well as during "turning gear" operation.

Open-loop regeneration ensures removal of extracted contaminants from the system, unlike closed loop dryers which actually recirculate contaminant within the hydrogen system.

The Dollinger HPS incorporates non-lubricated, two-way poppet valves, developed specifically for desiccant dryer service. They provide fast action, positive sealing, minimal pressure drop, and prevent crossport leakage.

Reliability:

• Complete regeneration of the desiccant is accomplished by a low-watt density heater. The heater is housed in a stainless steel tube to enhance regeneration and optimize desiccant life.
• Pilot operated switching valve incorporate stainless steel internals for reliable, trouble-free operation.
• Dryer chambers are epoxy painted and have 1/16-inch corrosion allowance for long service life.
• Pilot air filter protects valves, instruments and controls.
• Desiccant quality and life is enhanced by open loop regeneration and downflow drying.

Specifications:

Design Operating Conditions:  
Fluid: Hydrogen Gas
System Flow Rate: 8 - 12 ACFM
Operating Pressure (min/max): 10/75 psig
Inlet Temperature (max): 120° F
Outlet Moisture Content (dew point @ pressure): -40° F
Utilities:

 
Elec Class: NEMA 4
Elec Service: 115 / 60 / 1
Heater Size (per chamber): 1.8 kW
Motor Size:
1 hp
Pilot Air, separate source (min): 60 psig

Select one of the following to learn more:

AI - 128 - V Two Stage Air Intake Filter

AI - 104 Single Stage Air Intake Filter

AI - 187 Single Stage Air Intake Filter

Spin Filter

GP-146 Particulate Filter

GP-198 Coalescing Filter

LL-142 Liquid Filter

GP-154 Vacuum Filter

Oil Exhaust Filter

Gas Turbine Filter

Turbo Kleen Panel

Filter Elements

Filter Recovery Service

Hydrogen Purification

Order Filter Elements Online



HPS Features & Benefits

Switching valves and gas-tight blower are vented to prevent formation of dangerous air-hydrogen mixtures.

Welded piping minimizes threaded connections, thus reducing potential leak points.

Standard NEMA 4 enclosure provides weather-tight protection for controls.


Complete instrumentation continuously monitors system operation.

Potted conduit is built to ASME, ANSI, and NEC standards. Certification to CE, PED, and ATEX European standards is available upon request.

High Temperature heater shutdown prevents excessive operating temperature.

Chamber relief valves prevent overpressurization.

Direct connected heater wires eliminate potential for arcing across the terminal blocks in presence of moisture.

Purge exhaust drip leg ensures optimum regeneration and minimizes purge condensate back pressure.

Vent rotameter detects and measures any gross hydrogen leakage through system vent lines.
 