As
the pioneer in filtration, Dollinger has been solving most
demanding filtration problems for over 80 years. Today,
the protection of turbo machinery is measured in microns
- one reason the world's leading manufacturers continue
to rely on Dollinger's high-efficiency filtration products.
The TURBO KLEEN™ filter represents the latest in contamination
protection for your high-speed turbo machinery.
•
Improves turbine efficiency and fuel savings
• High efficiency ASHRAE media
• Maximum dust-holding capacity for extended life
• Rugged, high burst pressure design
Media:
• High efficiency ASHRAE tested media maximizes the
output of turbo machinery by removing microscopic particles,
which can foul and damage compressor blades.
•
Strong reinforced glass fiber media guarantees reliable
filtration, even under high velocity and turbulent operating
conditions, with no media shedding.
•
A highly permeable filter media that operates at a low clean
delta P resulting in improved performance and efficiency
of turbo machinery.
•
The TURBO KLEEN™ media features a graded pore structure,
which maximizes dust-holding capacity and extends the time
between filter changes, even under high dirt loading conditions.
Filter
Construction:
• The filter frame is a 100% polymeric and lightweight
design that's totally corrosion resistant and disposable
by incineration.
•
The TURBO KLEEN™ media is fully potted to the frame
creating a strong, high burst pressure design for trouble-free
operation under the most severe flow conditions.
•
The pre-mounted, seamless gasket creates a positive seal
for superior leak prevention.
Pre-Filters:
A
complete range of pre-filters is available to eliminate
coarse contaminant and extend the service life of the high
performance TURBO KLEEN™
filter.
Performance Data & Specifications:
Panel Element: 24" x 24" x 12"
Rated Flow: 3000 SCFM
Material: Frame - Polystyrene / Media -
Glass fiber, non-shedding
Minimum Removal Efficiency: 99.97% of 2
micron
Maximum Pressure Rating: 25 inches water
gauge
Maximum Temperature Rating: 200 F
Optional 0.3
micron TURBO KLEEN™ HP:
Panel
Element: 24"
x 24" x 11.5"
Rated Flow: 2,500 SCFM
Material: Frame - Polystyrene
/ Media - Glass fiber, non-shedding
Minimum Removal Efficiency: 99.97%
of 0.3 micron
Maximum Pressure Rating: 25 inches
water gauge
Maximum Temperature Rating: 200
F