Van Air's Dry Pak system is a complete skid mounted system
that guarantees clean, dry air for numerous air processes.
The Dry Pak can be installed indoors or outdoors to reduce
maintenance costs and prevent downtime in all painting,
shipbuilding, petrochemical and pneumatic processes.
Your
compressor not only compresses air, but also moisture vapor
(humidity) in the air. At high compressor discharge temperatures,
the air can hold a lot of moisture. However, air cools as
it travels through your piping, causing the moisture to
condense. Before you know it, you have a river of water
flooding expensive pneumatic equipment and tools.
Stop the river before it reaches your equipment. The Dry
Pak™ prevents condensation in your air lines and protects
pneumatic equipment. It saves time and money consumed by
air-operated equipment maintenance and downtime.
With a Dry Pak, you can finally stop asking why all the
water is in your air system.
•
Free Initial Desiccant Fill
• Mounted Filtration
• Dependable Motorized Drain Valve
• No External Energy Source (DP-375 to DP-1000)
• Ideal for Dirty or Dusty Environments
Applications:
Able to take inlet temperatures up to 150°F, the Dry
Pak can be installed indoors or outdoors. It keeps water
out of your pneumatic equipment by providing a dew point
10°F below the ambient temperature.
This protects your processes by ensuring clean, dry air
for :
• air tools
• painting
• ship building
• stationary blasting
• general shop air
• petrochemical processes
• pneumatic equipment
The optional freeze protection kit (Models DP-50 thru DP-250)
ensures operation in low temperatures.
Standard Equipment
• Air-Cooled Aftercooler
• (115V-1PH-60Hz motor
on DP-50 thru DP-250)
• (Air Motor on DP-350
thru DP-1000)
• Single Tower Deliquescent Desiccant Dryer
• Initial Supply of Dry-O-Lite® Desiccant
• Automatic Drain Valve
• (MDV-400I on models
DP-50 - 250)
• (PDV-500T Zero Loss
Drain on models DP-375-1000)
• Afterfilter (F200 series with B Grade Element)
• Filter Pressure Differential Indicator (PD-6)
• Interconnecting Piping and Fittings
• Steel Skid with Primer and Enamel Finish
• Filter-Regulator-Lubricator (FRL) installed for
DP-350 thru DP-1000 Air Motor
Accessories
High liquid level alarm (DP-100 and up)*.........P/N 26-3667
Pressure gauge kit (DP-100 and up)*.............P/N 29-0252
Temperature gauge kit (DP-100 and up)*........P/N 29-0326
Pressure/temp gauge kit (DP-100 and up)*.....P/N 29-0200
Freeze protection kit for operation below 32°F
Model FP-2 (DP-50 thru DP-250).......P/N 83-0762
Dry
Pak Desiccant Package System Dimensions
|
| Model
|
A
Height |
B
Width |
C
Depth |
D
Ht. to
Inlet |
E
Ht. to
Outlet |
In/Out
Conn. |
After-
Cooler
Model |
Cooler
Motor
HP |
Air
Motor
RPM |
Cooler
Volts
|
Dryer
Model |
Filter
Model |
Total
Weight |
|
DP-50 |
56 |
33 |
33 |
55 |
43 |
1 NPT |
AC-60-2 |
1/4 |
N/A |
115-1-60 TEFC |
D-8 |
F200-55-1/2-B-MD |
375 |
|
DP-100 |
57 |
45 |
41 |
55 |
42 |
1-1/2 NPT |
AC-100-2 |
1/4 |
N/A |
115-1-60 TEFC |
D-12 |
F200-100-1-B-MD |
550 |
|
DP-150 |
57 |
45 |
42 |
55 |
45 |
1-1/2 NPT |
AC-110-2 |
1/4 |
N/A |
115-1-60 TEFC |
D-16 |
F200-150-1-B-MD |
695 |
|
DP-250 |
60 |
49 |
48 |
59 |
46 |
2 NPT |
AC-120-2 |
(2) 1/4 |
N/A |
115-1-60 TEFC |
D-20 |
F200-265-1-1/4-B-MD |
970 |
|
DP-375 |
65 |
46 |
52 |
39 |
51 |
2 NPT |
AC-140-8 |
1 |
3450 |
N/A |
D-24 |
F200-350-1-1/2-B-MD |
1265 |
|
DP-500 |
70 |
50 |
53 |
39 |
52 |
2 NPT |
AC-150-8 |
1 1/2 |
3450 |
N/A |
D-30 |
F200-500-2-B-MD |
1975 |
|
DP-650 |
70 |
50 |
53 |
39 |
52 |
2 NPT |
AC-150-8 |
1 1/2 |
3450 |
N/A |
D-30 |
F200-600-3-B-MD |
1950 |
|
DP-800 |
76 |
70 |
74 |
40 |
56 |
3 NPT |
AC-160-8 |
1 1/2 |
1740 |
N/A |
D-36 |
F200-800-3-B-MD |
2865 |
|
DP-1000 |
106 |
80 |
88 |
40 |
100 |
3 NPT |
AC-170-8 |
3 |
1740 |
N/A |
D-42 |
F200-1000-3-B-MD |
4350 |
*
Models have a factory installed air motor with Filter-Regulator-Lubricator
(FRL).
** Weight includes desiccant. Desiccant shipped in
resealable pails for DP-50 through DP-375; bags for
DP-500 and larger.
Due to our policy of continuous improvement, dimensions
and specifications may change without notice.
Request certified drawing before purchasing.
Dry
Pak Desiccant Package System Maximum Capacities -
SCFM
| Model
|
80
PSIG |
90
PSIG |
100
PSIG |
125
PSIG |
|
DP-50 |
41 |
46 |
50 |
58 |
|
DP-100 |
83 |
91 |
100 |
102 |
|
DP-150 |
128 |
137 |
150 |
160 |
|
DP-250 |
206 |
228 |
250 |
275 |
|
DP-375 |
N/A |
342 |
375 |
384 |
|
DP-500 |
N/A |
456 |
500 |
650 |
|
DP-650 |
N/A |
593 |
650 |
650 |
|
DP-800 |
N/A |
730 |
800 |
871 |
|
DP-1000 |
N/A |
913 |
1000 |
1090 |
Capacities
based on rated conditions of 100 PSIG, 150°F inlet
and 10°F approach.
For 125 PSIG, capacities at pressures above 100 PSI
are determined by aftercooler rating at 10°F approach. |
|