Our
rugged F102 Series compressed air filter housings are welded
carbon steel, constructed and stamped in accordance with ASME
code Section VIII, Div. I code for 250 PSIG at 225° F.
All of our housings receive a rigorous hydrostatic pressure
test of 1.3 times the maximum working pressure.
The
exterior of the F102 Series filter housing is protected
by a coating of primer and air-dried machine enamel. The
interior of the housing is protected by alkyd enamel. Both
of these coatings help protect against corrosion, chipping
and cracking to ensure a long life for the filter housing.
By offering
9 different compressed air filter housings, with flows ranging
from 1,500 to 20,000 SCFM at 100 PSIG, Van Air has an F102
Series filter housing to meet a wide range of applications.
The filter inlet and outlet connections on the F102 Series
housings have port locations that allow for the installation
of pressure differential gauges to monitor the status of
your filter.
The
top-loading feature of the F102 Series filter housing allows
for the filter element to be easily replaced via an o-ring
sealed swing bolt closure. This top-loading feature allows
for the filter element to be replaced by one operator and
without concerns for ground clearance.
SELECTING A FILTER
To select
the appropriate filter, determine the following conditions
regarding the filter installation site:
• Maximum flow rate
• Min. and Max. operating pressures
• Operating temperature
• Degree of filtration desired
• Contaminants to be removed
Next, refer to the Flow Capacities chart below and locate
the column with your lowest operating pressure. Then find
the flow rate closest to, but greater than, that of your
system. Finally, read across to the left-hand column to
determine the filter model that will meet your needs.
You will now need to refer to the Filtration
Grades chart, also located below. Determine the element
grade that meets your needs. Be sure that the maximum inlet
temperature listed on the chart is sufficient for your operating
conditions.
Refer
to the Dimensions and Specifications chart and locate the
proper filter model number. Once you have located the model
number within the chart, verfiy that the inlet and outlet
connections are suitable for your piping. Also make sure
that there will be adequate clearance for element replacement.
FLOW
CAPACITIES - SCFM
| Model |
25
PSIG |
50
PSIG |
75
PSIG |
100
PSIG |
125
PSIG |
150
PSIG |
175
PSIG |
200
PSIG |
225
PSIG |
250
PSIG |
|
F102-1500-* |
520 |
845 |
1175 |
1500 |
1830 |
2155 |
2480 |
2810 |
3135 |
3460 |
|
F102-2000-* |
690 |
1130 |
1565 |
2000 |
2435 |
2870 |
3310 |
3745 |
4180 |
4615 |
|
F102-3500-* |
1210 |
1975 |
2735 |
3500 |
4265 |
5025 |
5790 |
6550 |
7315 |
8080 |
|
F102-5000-* |
1730 |
2820 |
3910 |
5000 |
6090 |
7180 |
8270 |
9360 |
10,450 |
11,540 |
|
F102-7500-* |
2595 |
4230 |
5865 |
7500 |
9135 |
10,770 |
12,405 |
14,040 |
15,675 |
17,310 |
|
F102-10,000-* |
3460 |
5640 |
7820 |
10,000 |
12,180 |
14,360 |
16,540 |
18,720 |
20,900 |
23,080 |
|
F102-12,500-* |
4325 |
7050 |
9775 |
12,500 |
15,225 |
17,950 |
20,675 |
23,400 |
26,125 |
28,850 |
|
F102-15,000-* |
5190 |
8460 |
11,730 |
15,000 |
18,270 |
21,540 |
24,810 |
28,080 |
31,350 |
34,620 |
|
F102-20,000-* |
6920 |
11,280 |
15,640 |
20,000 |
24,360 |
28,720 |
33,080 |
37,440 |
41,800 |
46,160 |
FILTRATION
GRADES
|
Application |
Element
Grade |
Purpose
|
Nominal
Particulate
Removal |
Element
Flow
Direction |
End
Cap
Color Code |
Aerosol
Removal
(Liquids) |
AA |
Extra Coarse Coalescing |
25.0 m |
IN / OUT |
Black |
|
A |
Coarse Coalescing |
5.00 m |
IN / OUT |
Green |
|
B |
General Purpose
Coalescing |
1.00 m |
IN / OUT |
Red |
|
C |
High Efficiency
Coalescing |
0.01 m |
IN / OUT |
Blue |
Solid
Particulate
Removal |
RAA |
Extra Coarse Coalescing |
25.0 m |
OUT / IN |
Black |
|
RA |
Coarse Coalescing |
5.00 m |
OUT / IN |
Green |
|
RB |
General Purpose
Coalescing |
1.00 m |
OUT / IN |
Red |
|
RC |
High Efficiency
Coalescing |
0.01 m |
OUT / IN |
Blue |
|
HT |
High Temperature
Particulate |
1.00 m |
OUT / IN |
Zinc Plate
or
Galvanized |
Oil
Vapor
Removal |
RD |
Vapor Adsorbing |
0.01 m |
OUT / IN |
Black |
| Maximum
Working Pressure |
| All
Standard Models |
250
PSIG |
| High
Temperature Models (HT) |
165
PSIG |
| Special
Models |
Consult
Data Plate |
| |
| Ambient
Temperature |
| Minimum |
35°
F |
| Maximum |
150°
F |
|
| Maximum
Inlet Temperature |
| AA,
A, RAA, RA, RB, & RC Series |
225°
F |
| B
Series |
175°
F |
| C
Series |
125°
F |
| RD
Series |
80°
F |
| HT
Series |
450°
F |
|
DIMENSIONS
AND SPECIFICATIONS
| Model |
Flow1
(SCFM) |
In
/ Out
Conn.
(Inches) |
Drain
Conn.
(NPT) |
A |
B |
C |
D |
E |
F |
Weight2
(lbs) |
|
F102-1500-* |
1500 |
3 FLG |
1" |
18 3/4 |
10 3/4 |
32 |
70 3/4 |
82 |
24 |
309 |
|
F102-2000-* |
2000 |
4 FLG |
1" |
18 3/4 |
10 3/4 |
33 1/2 |
78 1/2 |
89 1/2 |
30 |
337 |
|
F102-3500-* |
3500 |
6 FLG |
1" |
24 3/4 |
12 3/4 |
32 |
77 1/2 |
92 |
30 |
420 |
|
F102-5000-* |
5000 |
6 FLG |
1" |
28 |
16 |
33 1/2 |
78 1/2 |
93 |
30 |
582 |
|
F102-7500-* |
7500 |
8 FLG |
1" |
32 |
20 |
34 1/2 |
80 1/2 |
98 1/4 |
30 |
823 |
|
F102-10,000-* |
10,000 |
10 FLG |
1" |
36 |
24 |
35 1/2 |
83 3/4 |
104 1/4 |
30 |
1089 |
|
F102-12,500-* |
12,500 |
10 FLG |
1" |
36 |
24 |
35 1/2 |
83 3/4 |
104 1/4 |
30 |
1130 |
|
F102-15,000-* |
15,000 |
12 FLG |
1" |
42 |
30 |
44 1/2 |
94 3/4 |
117 3/4 |
30 |
1771 |
|
F102-20,000-* |
20,000 |
16 FLG |
1" |
52 |
36 |
46 |
99 1/4 |
126 |
30 |
2428 |
* Insert
appropriate filtration grades here; for example F102-1500-B.
1 Flow is based on SCFM @ 100 PSIG @ 100° F.
2 Weight includes housing and elements.
• Due to continuous improvement, dimensions and specifications
may change without notice.
• Request certified drawing before pre-piping.
|
|
|